NYCY 0,6/1 kV

Appearance:
High-tension cable (2.5 mm² – 6 mm²)

Usage:
Power cable to be put in the ground, in inside areas, cable ducts and outside when no special mechanical loads are expected. This "German" ground cable (according to DIN VDE0271 and IEC 502) can be used in The Netherlands as a temporary ground cable. The cable conforms to the 73/23/EEG guideline (CE).

Properties:

  • Maximum continuous conductor temperature 70 C°
  • Available in custom sizes

Structure:
Conductor:
Solid bare electrolytic copper
Insulation:
Polyvinylchloride (PVC), colour-coded
Cores:
Solid
Covering:
Common core covering
Outer jacket:
Polyvinylchloride (PVC)
Jacket colour:
Black

Electrical details:
Nominal voltage: 600/1000 Volt
Tested voltage: 4000 Volt

Core colours:
2 cores: Brown, blue
3 cores: Black, brown, grey
4 cores: Black, blue, brown, grey
5 cores: Black, blue, brown, black, grey

Supplied:
All sizes: On reels

 

print

Number of cores and nominal conductor diameter
(n x mm²)
Nominal outside diameter
(mm)
Approximate weight
(kg/km)
Minimum bending radius
(mm)
Permissible current underground*
(A)
Permissible current in open air**
(A)
2 x 1,5 13 200 156 27 19.5
2 x 2,5 14 260 167 36 26
2 x 4 16 350 180 47 34
2 x 6 17 430 210 59 44
3 x 1,5 17 220 204 27 19.5
3 x 2,5 18 280 216 36 26
3 x 4 20 390 240 47 34
3 x 6 21 500 252 59 44
4 x 1,5 18 250 216 27 19.5
4 x 2,5 19 340 223 36 26
4 x 4 21 460 252 47 34
4 x 6 22 580 264 59 44
5 x 1,5 19 290 220 27 19.5
5 x 2,5 20 420 234 36 26
5 x 4 22 540 250 47 34
5 x 6 23 670 276 59 44

 

*) In the ground, at 20 C°.
**) In the open air, at 30 C°.

NYCWY 0,6/1 kV

Appearance:
High-tension cable (10 mm² – 240 mm²)

Usage:
Power cable to be put in the ground, in inside areas, cable ducts and outside when no special mechanical loads are expected. This "German" ground cable (according to DIN VDE0271 and IEC 502) can be used in The Netherlands as a temporary ground cable. The cable conforms to the 73/23/EEG guideline (CE).

Properties:

  • Maximum continuous conductor temperature 70 C°
  • Available in custom sizes

Structure:
Conductor:
Solid or twisted bare electrolytic copper
Insulation:
Polyvinylchloride (PVC), colour-coded
Cores:
Twisted together
Plaiting/protective covering:
Concentric conductors consisting of copper wires
Covering:
Common core covering or wrapping
Outer jacket:
Polyvinylchloride (PVC)
Jacket colour:
Black

Electrical details:
Nominal voltage: 600/1000 Volt
Tested voltage: 4000 Volt

Core colours:
3 cores: Black, brown, grey
4 cores: Black, blue, brown, grey

Supplied:
All sizes: On reels

print

Number of cores and nominal conductor diameter
(n x mm²)
Nominal
outside diameter
(mm)
Approximate weight
(kg/km)
Minimum bending radius
(mm)
Permissible current underground*
(A)
Permissible current in open air**
(A)
3 x 10RE/10 20 775 240 75 60
3 x 16RE/16 22 1060 258 98 80
3 x 25RM/16 27 1525 330 123 106
3 x 35SM/35 26 1902 312 157 131
3 x 50SM/50 30 2516 366 135 159
3 x 70SM/35 33 3094 396 223 202
3 x 95SM/50 38.5 4176 456 275 244
3 x 120SM/70 41.5 5193 492 313 282
3 x 150SM/70 45.5 6220 546 353 324
3 x 185SM/95 50 7798 600 399 371
4 x 10RE/10 21 914 252 75 60
4 x 16RE/16 23.5 1216 288 98 80
4 x 25RM/16 29 1832 354 128 106
4 x 35SM/16 29 2165 348 157 131
4 x 50SM/25 33.5 2950 402 185 159
4 x 70SM/35 37 3946 444 228 202
4 x 95SM/50 43 5344 516 275 244
4 x 120SM/70 46.5 6682 564 313 282
4 x 150SM/70 51.5 8022 612 353 324
4 x 185SM/95 56.5 10084 673 399 371
4 x 240SM/120 60 11650 720 464 436

 

*) In the ground, at 20 C°.
**) In the open air, at 30 C°.