Welding cable

Cable

Welding cable

H01N2-D

Appearance:
Welding cable (16 mm² - 120 mm²)

Usage:
In dry, damp and wet areas as well as outside, as machine and manual welding cable. Especially suitable for the secondary side of a welding transformer. Can also be used as low-voltage cable with accu batteries.

Properties:

  • Self-extinguishing.
  • Immune to greases and oils.
  • Well able to whitstand weather influences such as ozone. 
  • Very flexible.

Structure:
Conductor:
Very flexible bare electrolytic copper.
Wrapping:
By one or more separating layers.
Outer jacket:
Vulcanised synthetic rubber on basis of polychloroprene (PCP).
Jacket colour:
Black (other colours available on request).

Electrical details:
Nominal voltage: 100/100 Volt
Tested voltage: 1000 Volt

Supplied:
16 - 50 mm² : On rings and reels
> 70 mm² : On reels

print

Number of cores and nominal conductor diameter
(n x mm²) 
Nominal outer diameter
(mm)
Minimum bending radius*
(mm)
Permissible current***
(A)
Maximum tensile strength**
(N)
Approximate Weight
(kg/km)
16 10.2 45 148 240 220 
25 11.6 58 204 380 320 
35 12.8 77 260 530 420 
50 14.7 88 336 750 590 
70 17 102 426 1050 790 
95 19.4 116 523 1430 1060 
120 21.3 128 613 1800 1290

*) With cable moving freely.
**) Static tensile power. Even when used dynamically, when higher forces often occur, the stated tensile forces schould not be exceeded.
***) In intermittent usage (such as during welding), when operating periods of 5 minutes and a switch-on factor of 60%, in accordance with NPR 3627.
****) When power is turned on continuously. 

Bos elektro bv ©  |  Oscar Romerolaan 12 , 1216 TK, Hilversum  |  E-mail  |  Telefoon +31 (0)35 623 6000  |  Fax +31 (0)35 623 5968  |  Disclaimer  |  Privacy